Cascade Control | Basic Process Control Strategies and

A common implementation of cascade control is where a flow controller receives a setpoint from some other process controller (pressure, temperature, level, analytical, etc.), fluid flow being one of the fastest-responding process types in existence. A feedwater control system for a steam boiler shown here in pneumatic form is a good

Learn More

Superheaters - an overview | ScienceDirect Topics

One of the main differences between the superheater and reheater is the steam pressure. The outlet pressure of the superheater in a subcritical drum boiler, for example, is for example at 18.6 MPa, while the outlet pressure of the reheater is only 4.0 MPa.When a supercritical boiler is operated under normal load, the heating surfaces of the reheater and superheater have to increase in order to

Learn More

Uses of Refrigeration Low Pressure Controls | Industrial

Dec 13, 2010 · The cut-in is the pressure that closes the LPCs contacts and starts the compressor. This pressure relates to the refrigerated boxs highest temperature. As an example for a beer cooler: The desired box temperature is 36 ° F; the system is R-134A refrigerant. From a pressure/temperature chart, we see that 31.3 psig is 36 ° F for R-134A.

Learn More

The Only Boiler Maintenance Checklist You Will Ever Need

Nov 18, 2020 · 1. Check boiler water level in the sight glass and the steam pressure on the gauge to the steam boilers. Check temperature reading and water pressure on hot water boilers. Record this in your logbook. 2. Check the low water cutoff operation by opening the blow down valve on the low water cutoff to remove rust and dirt.

Learn More

Overview of Woodward Governor 505 | Instrumentation Tools

Hydraulic Amplifier is a linear electro-hydraulic actuator designed to operate steam turbine control valves or valve racks. This integrated actuator is intended for use on mechanical-drive or generator-drive steam turbines, and uses a low-pressure hydraulic oil source (typically turbine

Learn More

Steam System Design and Best Practices Related to Kiln Drying

Low pressure steam supply to deareator To Boiler. New England Kiln Drying Association Steam Design & Best Practices HerLine Technologies Adds additional system devices such as pressure reducing valves and safety valves to be concerned with acting upon any steam component such as a trap, valve, etc.. Flow Elevation Changes.

Learn More

Feedforward Control | Basic Process Control Strategies and

Feedforward is a rather under-used control strategy capable of managing a great many types of process problems. It is based on the principle of preemptive load counter-action: that if all significant loads on a process variable are monitored, and their effects on that process variable are well-understood, a control system programmed to take appropriate action based on load changes will

Learn More

Heating System Boiler Check Valves, Flow Control Valves

Steam boiler automatic water feed valves are discussed . at WATER FEEDER VALVE, STEAM. While going through the detailed sequence in the operation of the heating boiler, watch for and inspect the condition of the heating boiler controls and safety devices (as required by ASHI 9.1.A.3 automatic safety controls).

Learn More

Flowmeters | Dwyer Instruments

Dial Dwyer offers different types of Dial Flowmeters for various applications. Flow meters measure water, oil, gas or air flow rates. Applications include calculating required fill or drain times for tanks, water towers, backflow prvention, heat exchangers, and oil & gas equipment.

Learn More

Combustion Safety - Honeywell

NFPA 85, Boiler and Combustion Systems Hazards Code, applies to single burner boilers, multiple burner boilers, stokers, and atmospheric fluidized-bed boilers with a fuel input rating of 12.5 million BTU/hr or greater, and to fired or unfired steam generators used to recover heat from combustion turbines.

Learn More